| Model | 3-in-1 (626X+7605+7721) |
| Test Channels | 20 |
| Hi pot Channels | 1 (7605) |
| Max. Frequency | 1MHz (6267) |
| Hi pot Voltage | AC 5000V / DC 6000V |
| Surge Voltage Test | 200V-5000V |
| Software | PC Link (optional) |
| 6265 | 6266 | 6267 | |
|---|---|---|---|
| Frequency | 10Hz-200kHz | 10Hz-500kHz | 10Hz-1MHz |
| Frequency Resolution | 5 digits |
| Basic Accuracy | ±0.1% |
| AC Drive Level | 10mV-2Vrms |
| DC Drive Level | 10mV-2V |
| Output Impedance | 100Ω |
| Turn Test | Inductance or voltage test, frequency 50Hz-200kHz |
| Test Mode | Meter Mode / List Mode |
| Parameters | L, Z, C, R, G, B, Y, ACR, Q, θ, DCR, Leakage Inductance (LK), Turn, Pin-Short, Balance, Phase (PH) |
| L, LK | 0.1nH – 9999.99H |
| C | 0.00001pF – 999.99mF |
| Q, D | 0.00001 – 99999 |
| Z, X, R | 0.00001Ω – 99.9999MΩ |
| Y | 0.01nS – 99.9999S |
| θ | -180° – +180° |
| DCR | 0.1mΩ – 99.999MΩ |
| Turn Range | 0.1 – 99999.9 turns |
| Pin-Short | 12 pairs, between pin to pin |
| AC Hi pot | DC Hi pot | IR | |
|---|---|---|---|
| Output Voltage | 10V-5000V | 10V-6000V | 10V-1000V |
| Voltage Resolution | 1V | 1V | 1V |
| Voltage Accuracy | ±(3% of setting +5V) | ±(3% of setting +5V) | - |
| Test Range | 0.001-31mA | 0.001-11mA | 1-12000MΩ |
| Arcing Detection | 0-20 | 0-10 | - |
| Measuring Time | 0.1-999s |
| Ramp Time | 0.1-10s |
| Time Resolution | 0.1s |
| Impulse Voltage | 200V-5000V |
| Area Comparison | Layer shorts increase coil power loss and resonance damping; the resonance amplitude and total wave area decrease. Comparing the area detects layer short circuits. |
| Area Differential | Sums the difference between reference wave and DUT wave. A layer short reduces inductance and shifts the wave phase, increasing the differential area. |
| Waveform Comparison | A tolerance band around the reference wave; the DUT passes if its wave stays inside. Judges amplitude and phase of the resonance wave. |
| Corona | Counts corona discharges caused by insulation defects during the pulse test. |
| Flat | Layer shorts make the waveform tremble; the instrument quantizes and compares this trembling. |
| Transformer Tester (6265/6266/6267) | Impulse Tester (7721) | Hi pot Tester (7605) | |
|---|---|---|---|
| Built-in Storage | 128 sets | 200 sets | - |
| Power Supply | 98-132Vac / 195-264Vac, 47-63Hz | 115/230Vac ±15%, 50/60Hz ±5% | 98-132Vac / 195-264Vac, 47-63Hz |
| Power Consumption | 600VA/set | 600VA/set | 600VA/set |
| Dimensions (W×H×D) | 344×145×343 mm | 435×190×522 mm | 435×145×500 mm |
| Weight | 9 kg | 14 kg | 15 kg |
| Interface | RS-232, Handler, LAN, USB Host, EXT. I/O | RS-232, Remote, Printer | RS-232, Remote, USB Host, USB Device, EXT. I/O |
| Display | 7" TFT (800×480), Farbe | 5.7" TFT (320×240) | 4.3" TFT (480×272), Farbe |