The 2-in-1 test system consists of a transformer tester (626x) and a HiPot tester (7631) and the
associated pneumatic scan box (7721). With this test system, many components can be tested in one work step.
With an AC output voltage of 5kV and a DC output voltage of 6kV, it is possible to perform "high voltage"
and "low voltage" tests in one test cycle and also test multiple sets of windings.
The transformer tester (model 6265/6266/6267, test frequency 200kHz/500kHz/1MHz, 20 channels) has
a basic accuracy of up to ±0.1%. Due to the built-in LCR meter function in the transformer tester,
it can be used as an LCR meter. The system supports USB Host, RS-232, external I/O handlers and LAN
interfaces. A PLC/SPS interface for control in your automated production is also available.